Workplace Fire Safety Tips

Workplace Fire Safety: 8 Prevention Tips

Use this link to make 9 Posts

Workplace fires put businesses and their employees at significant risk every year. In 2022 alone, the U.S. had more than 140,000 non-residential structure fires, resulting in more than $4 billion in property damage and losses, according to the National Fire Protection Association (NFPA). Few scenarios are more frightening than a workplace fire. Unpredictable, life-threatening, and difficult to recover from, a major fire in the workplace can disrupt operations for weeks or even months. Not to mention, your people’s lives are on the line, and it’s your responsibility to protect them. Protecting your organization from the threat of fires begins with prevention and basic fire safety. While some situations are out of a company’s control (wildfires or arson, for example), most workplace fires can be avoided by understanding fire hazards, taking precautions, and creating an emergency action plan.

Whether you are creating a new fire safety program for your business or want to ensure your organization is covered, here are eight workplace fire safety tips that can help you prevent and mitigate the risk of fire to your people and operations.

Does Arizona Recognize NFPA Fire Codes

Does Arizona Recognize NFPA Fire Codes?

No, Arizona does not adopt NFPA fire codes directly; instead, the state adopted the 2018 International Fire Code (IFC) as the “Arizona Fire & Medical Authority Fire Code,” and individual jurisdictions can have additional local amendments to the base codes. While some jurisdictions may reference NFPA standards as guidelines or for specific areas, such as fire sprinklers, the primary state-level building and fire safety standards are based on the International Code Council (ICC)’s International Fire Code, not the National Fire Protection Association (NFPA) codes. The degree of adoption and the specific versions used vary depending on the local authority.


Key details on how NFPA codes are used in Arizona:

  • Widespread reference: NFPA standards are widely used in Arizona as the national benchmark for fire and life safety. For example, the Phoenix Fire Department requires that licensed fire protection contractors work in accordance with NFPA standards.
  • Adoption of the IFC: The state has adopted the International Fire Code (IFC), which frequently references and defers to specific NFPA standards. For example, the Arizona Fire & Medical Authority’s adoption of the 2018 IFC also adopts the most recent edition of NFPA codes and standards.
  • Local jurisdiction authority: Local jurisdictions, or Authorities Having Jurisdiction (AHJ), can amend or adopt different editions of the codes.
    • For instance, the City of Maricopa has adopted the 2018 IFC with its own specific amendments.
    • Some jurisdictions may use older versions of the codes, so it’s best to check with the local AHJ to see which edition applies.
  • Specific NFPA standards: NFPA codes such as NFPA 72 (fire alarm systems) are often specifically cited for fire system installations. Other specialized standards, like those for battery energy storage systems, reference NFPA 68 and 69.

Call: (888) 864-4362
Email: Info@IntelligentFire.com
Contact Us: Schedule a Call

 

Relevant Keywords:
Authorities Having Jurisdiction
International Fire Code
Arizona Fire & Medical Authority
Intelligent Fire
Specific NFPA Standards

Does Nevada Recognize NFPA Fire Codes

Does Nevada Recognize NFPA Fire Codes?

Yes, Nevada recognizes and has adopted specific National Fire Protection Association (NFPA) fire codes, including NFPA 101 for life safety and NFPA 13 for sprinkler systems.


Key NFPA Standards & Their Status in Nevada:

  • NFPA 101, Life Safety Code: Nevada’s State Fire Marshal has formally adopted the NFPA 101 code, which outlines requirements for building design, construction, and operation to protect occupants from fire. The state’s adoption of the 2021 edition is a current example of this recognition.
  • NFPA 13, Standard for the Installation of Sprinkler Systems: Nevada utilizes NFPA 13 as the basis for its state sprinkler code, with the 2022 edition having been adopted.
  • NFPA 70, National Electrical Code (NEC): The NEC is also a critical, widely adopted NFPA standard. In 2024, the State of Nevada’s Public Works Division referenced the 2017 NEC as part of its adopted codes.
  • Nevada Administrative Code (NAC): The NAC references and incorporates these NFPA standards, defining “N.F.P.A.” as the National Fire Protection Association. The NAC also states that approved sprinkler systems must meet the requirements of the appropriate NFPA standard.

Additionally, local jurisdictions within Nevada may adopt their own specific versions or amendments of model codes. It is important to consult with your local fire authority for the most current fire code information.


Call: (888) 864-4362
Email: Info@IntelligentFire.com
Contact Us: Schedule a Call

 

Relevant Keywords:
NFPA Fire Codes
Nevada Administrative Code (NAC)
National Fire Protection Association (NFPA)
State-Specific Amendments
Fire Protection Experts

Does California Recognize NFPA Fire Codes

Does California Recognize NFPA Fire Codes?

No, California does not directly adopt the NFPA codes; instead, the state bases its California Fire Code (CFC) on the International Fire Code (IFC) with amendments, while also referencing and incorporating specific NFPA standards for certain fire protection systems and components, such as NFPA 13 for sprinklers and NFPA 72 for fire alarms, within the CFC.


Here’s a breakdown of how California uses NFPA codes:

  • California Fire Code (CFC): The primary state fire code, which is based on the International Fire Code (IFC).
  • Referencing NFPA Standards: The CFC incorporates specific requirements from various NFPA standards for different aspects of fire safety. For example:
    • NFPA 13: For automatic sprinkler systems in one- and two-family dwellings, townhouses, and Group R-3 and R-4 conditions.
    • NFPA 72: For fire alarm shop drawings and the preparation of systems.
    • NFPA 110 and 111: For the installation of emergency power systems.
    • NFPA 25: For inspection and maintenance of sprinkler systems in commercial and industrial buildings.
    • NFPA 170: For the use of specific symbols on fire safety and emergency system drawings.
  • State-Specific Amendments: The CFC includes amendments and additions to the base IFC, ensuring that the code is tailored to California’s specific needs.
  • Integrated Code: The CFC is integrated into California’s broader Title 24 Building Standards Code, which serves as a comprehensive set of regulations for fire safety and prevention.

Call: (888) 864-4362
Email: Info@IntelligentFire.com
Contact Us: Schedule a Call

 

Relevant Keywords:
NFPA Fire Codes
California Fire Code (CFC)
State-Specific Amendments
Integrated Code
Fire Protection Experts

Who is a qualified person for NFPA 70E?

An NFPA 70E-qualified person is an individual who has demonstrated the necessary skills and knowledge in the construction and operation of electrical equipment and installations, and has received safety training to identify, assess, and avoid electrical hazards. This designation is made by the employer and requires the individual to be proficient in safety techniques, the proper use of Personal Protective Equipment (PPE), specialized tools, and emergency procedures.  

Key Characteristics of a Qualified Person
  • Demonstrated Skills and Knowledge:

The individual must show competence in understanding the equipment’s construction and operation. 

  • Safety Training:

They must have received specific training to recognize and avoid electrical hazards. 

  • Familiarity with Safety Measures:

This includes knowledge of special precautionary techniques, proper use of PPE, insulated tools, and test equipment. 

  • Hazard Identification:

A qualified person can distinguish energized parts from other equipment components and determine nominal voltages. 

  • Risk Assessment:

They can plan work, identify hazards, assess risks, and select appropriate controls using the hierarchy of controls. 

  • Employer Designation:

The employer is the one to officially designate an employee as a qualified person, based on demonstrated competency. 

What’s Required to Become Qualified
  • Training:
    Specialized training in electrical safety and hazard recognition is mandatory. 

  • On-the-Job Experience:
    The designation often requires subsequent on-the-job training and supervision. 

  • Validation of Competency:
    Employers must validate an individual’s skills and knowledge before they can be considered qualified for specific tasks. 

  • Documentation:
    All training and qualifications must be properly documented. 

Important Considerations
  • Specificity of Qualification:
    A person can be qualified for some equipment or tasks but not others, depending on their employer’s training program. 

  • Employer Responsibility:
    The employer bears the ultimate responsibility for determining an individual’s qualification status.

Inventory Liquidation

Inventory Liquidation – Limited Stock on Overstock Parts!

We’re clearing out excess inventory on select fire system components.

 

Shop Clearance Parts:

Vesda – VEP-A-10: Vesda Detector with 3.5″ Display UL 6th Edition

Vesda – VES-A-10: Vesda Detector with 3.5″ Display UL 6th Edition

 

Take advantage of while supplies last. Once they’re gone, they’re gone!


Call: (888) 864-4362
Email: Info@IntelligentFire.com
Contact Us: Schedule a Call

 

Relevant Keywords:
Vesda
VEP-A-10
VES-A-10
Overstock
Inventory Liquidation

Q&A: 12-Year Hydrostatic Testing

12-Year Hydrostatic Testing – What You Need to Know

Q: What is 12-Year Hydrostatic Testing?

A: Hydrostatic testing is a critical fire safety requirement mandated by NFPA standards. Every 12 years, fire extinguishers and certain fire suppression cylinders must undergo pressure testing to verify they can safely hold their extinguishing agent under extreme conditions. This process ensures the reliability of your life-saving equipment when you need it most.


Q: Why is it so important?

A: Fire extinguishers and cylinders may look fine on the outside, but years of wear, corrosion, or damage can weaken their integrity. Hydrostatic testing exposes cylinders to high-pressure water testing to confirm they are safe, compliant, and ready for action. Skipping this step could result in equipment failure during a fire—putting people, property, and compliance at risk.


Q: What does the process involve?

A:
When Intelligent Fire performs a 12-year hydrostatic test, you can expect:

  • Visual Inspection – Checking for wear, damage, or corrosion.

  • Pressure Test – Filling the cylinder with water and applying pressure beyond its normal operating level.

  • Leak & Integrity Verification – Ensuring there are no leaks, bulges, or weaknesses.

  • Reassembly & Recharging – Restoring the extinguisher or cylinder to full working order.

  • Documentation – Detailed records for compliance with NFPA and OSHA requirements.


Q: Who is required to do it?

A: All businesses, facilities, and organizations that use portable fire extinguishers, clean agent cylinders, or certain suppression system tanks are required to comply. OSHA and NFPA both mandate hydrostatic testing intervals—and inspectors will flag any overdue equipment.


Q: How does Intelligent Fire help?

A: We make compliance simple. Intelligent Fire Systems & Solutions provides:

  • Certified technicians who perform testing with precision and care.

  • Convenient scheduling to minimize downtime.

  • Full reporting for code compliance and insurance requirements.

  • Peace of mind knowing your fire protection is safe, legal, and reliable.


🔒 The Bottom Line

Your fire safety equipment is only as reliable as its last test. With Intelligent Fire’s 12-Year Hydrostatic Testing services, you ensure your extinguishers and suppression cylinders deliver when seconds matter most.

Don’t risk non-compliance or equipment failure—schedule your hydrostatic testing today.

The 5-year sprinkler inspection

The 5-year sprinkler inspection, mandated by the National Fire Protection Association (NFPA) Standard 25, is a comprehensive internal assessment of the system. It goes beyond the standard annual visual check to identify and address issues like corrosion, blockages, and component degradation that can accumulate over time.

NFPA 25 requirements for the 5-year inspection

  • Internal Piping Assessment: An inspector opens flushing connections and removes a sprinkler head from the end of a branch line to look for foreign materials inside the pipes. This is designed to identify obstructions such as rust, sludge, mineral deposits, and microbiologically influenced corrosion (MIC) that could impede water flow.
    • Obstruction Investigation: If significant obstructions are found during the initial internal inspection, a more comprehensive obstruction investigation is required at multiple points in the system, including the system valve, riser, and cross main.
    • Multiple Wet Pipe Systems: In buildings with multiple wet pipe systems, an internal inspection is performed on every other system during each 5-year cycle. However, if obstructions are found in one system, all systems in the building must be inspected.
  • Gauge testing or replacement: All pressure gauges must be replaced or tested against a calibrated gauge to ensure they are accurate.
  • Valve inspection: All system valves, including alarm, dry, and deluge valves, must be opened and inspected internally to ensure all components are working correctly and are free of foreign material.
  • Standpipe system flow test: A flow test is performed on all automatic standpipe systems to verify that the required water pressure and flow are available at the most remote hose valve outlets.
  • Standpipe hydrostatic testing: Manual standpipe systems are hydrostatically tested at a pressure of at least 200 psi for 2 hours every five years.
  • Fire Department Connection (FDC) inspection: The FDC piping is inspected to ensure it is clear of blockages. This may include back-flushing and hydrostatic testing.
  • Alternative testing methods: The use of alternative, non-destructive testing methods for internal piping assessment may be permitted by the authority having jurisdiction (AHJ), but a direct internal inspection is often considered the gold standard.

Who is responsible for compliance?

While the NFPA sets the national standard, enforcement and specific requirements are determined by the Authority Having Jurisdiction (AHJ), which is typically a local fire department or municipal fire marshal. It is the building owner or manager’s responsibility to ensure inspections are performed by a qualified and licensed fire protection contractor and that all reports are properly documented.

5-Year Sprinkler Inspection Requirements

A 5-Year Sprinkler Inspection

Requires opening parts of the system, like a main and branch line, to check for internal obstructions from foreign material such as rust or sludge, which could impede water flow during a fire. Other common 5-year requirements include internally inspecting and cleaning check valves, testing or replacing pressure gauges, performing flow tests on standpipes and the Fire Department Connection (FDC), and inspecting water storage tanks. These inspections are mandated by NFPA 25 to ensure the system’s internal components are clean and functional when needed.


Key Components Inspected During a 5-Year Inspection

  • Internal Piping: Technicians remove a sprinkler head and open a flushing connection at the end of a main to inspect the piping for organic and inorganic foreign material that could cause blockages.
  • Check Valves: The internal components of check valves are inspected to ensure they operate correctly and are free from obstructions.
  • Pressure Gauges: Gauges are either tested for accuracy by comparison with a calibrated gauge or replaced entirely.
  • FDC & Standpipe Flow Tests: A flow test is performed on the Fire Department Connection (FDC) and standpipe systems to verify they can deliver the required flow and pressure.
  • Water Storage Tanks: For systems with a water storage tank, a licensed professional inspects the interior for corrosion, pitting, or cracks.
  • Alarm and Dry/Deluge/Pre-action Valves: All system valves are inspected internally to confirm their components are functional.

Why the Inspection Is Necessary

  • Prevent Obstructions: This inspection is crucial for identifying blockages, such as rust, slime, or other debris, that can accumulate inside pipes and sprinklers, hindering water flow during a fire.
  • Ensure System Integrity: By checking internal components, the inspection helps confirm that the system can perform its life-saving function when it’s most critical.
  • Comply with Codes: The requirements for the 5-year inspection are outlined in NFPA 25, the standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems.

Call: (888) 864-4362
Email: Info@IntelligentFire.com
Contact Us: Customer Support

 

Relevant Keywords:
>
>
>
>
>

CyberSecurity for Wireless Fire Alarm Systems

How does NFPA 72 Address CyberSecurity for Wireless Fire Alarm Systems?

With the increasing connectivity of modern fire alarm systems, the National Fire Protection Association (NFPA) has expanded its guidelines to address cybersecurity risks. Beginning with the 2022 edition of NFPA 72, the code introduced a new chapter focused on cybersecurity, which has since been made more prescriptive in the 2025 edition.

NFPA 72 Cybersecurity Provisions (2025 edition)

Instead of providing a specific cybersecurity checklist, the NFPA references established standards and focuses on risk-based measures. For fire alarm systems, particularly wireless ones that interface with other networks or the internet, NFPA 72 requires the adoption of security frameworks.
  • Security levels: The 2025 edition mandates specific security levels for interfaces communicating with network-connectable equipment. Systems that are not connected to the internet and use proprietary, wired protocols are considered to have the lowest security risk and do not require minimum cybersecurity levels.
  • Manufacturer responsibility: Many of the requirements focus on manufacturers, mandating that they design and build their equipment to meet specific cybersecurity standards, such as UL 2900-2-3, and provide evidence of compliance with these standards.
  • Integration with other standards: For fire alarm and signaling systems susceptible to cyber threats, NFPA 72 requires coordination with established cybersecurity frameworks. These include standards from the National Institute of Standards and Technology (NIST) and the International Society of Automation (ISA).

Remote Access & System Security

The use of wireless technology often includes remote access features for testing, maintenance, and programming. NFPA 72 includes specific safeguards for this functionality to prevent unauthorized access.
  • Manual termination: There must be a physical means to manually shut off a remote connection at the fire alarm control panel at any time.
  • Inactive time-out: Remote connections must automatically terminate after one hour of inactivity.
  • On-site verification: Key functions, such as silencing or resetting the system, must be enabled by a qualified person who is physically present on-site. The remote operation is limited to the specific portion of the system that has been taken out of service.
  • Owner access: Building owners must be given access to software security credentials. This prevents an installer or service contractor from holding access “hostage” if an owner decides to switch to a different provider.

Cybersecurity Definition in NFPA 72

The 2025 edition includes a clear definition of cybersecurity within the code.
  • NFPA 72 definition: “The protection of systems from theft or damage of data, or damage to hardware or software, as well as from unauthorized command or control or access to any information or any services the systems provide”.

How Cybersecurity Applies to Wireless Fire Alarm Systems

Wireless systems are inherently more reliant on networks than fully wired, isolated systems, making these cybersecurity provisions particularly relevant. For wireless systems that connect to the internet, build networks, or use remote monitoring, owners and contractors must implement protections such as secure gateways or firewalls. The manufacturer is responsible for providing equipment that meets the referenced security standards, while the owner is accountable for implementing appropriate access controls and managing the system’s network connections.

Call: (888) 864-4362
Email: Info@IntelligentFire.com
Contact Us: Customer Support

 

Relevant Keywords:
>
>
>
>
>